Comprehensive study of cost, seismic & wind impacts on circular water tanks with varying cylindrical height-to-diameter ratio

Authors

  • Sukanya Saxena Indian Institute of Technology (B.H.U) Varanasi 221005 India
  • Krishna Kant Pathak Professor Department of Civil Engineering Indian Institute of Technology (B.H.U) Varanasi 221005 India

DOI:

https://doi.org/10.56042/ijems.v31i2.5368

Keywords:

Elevated water tanks, Circular tanks, RCC structures, Staging, Base shear, Seismic loads, Wind loads, Limit state method of design

Abstract

This study systematically assesses the cost and material efficiency of circular water tanks with varying capacities, closely examining the influence of cylindrical height-to-diameter (H/D) ratios within the range of 0.2 to 2.0. The investigation delves comprehensively into the effects of wind and seismic forces, accounting for both tank-filled and empty conditions across the entire spectrum of H/D ratios. The analysis specifically focuses on water storage capacities of 600, 700, 800, 900, 1000, 1100, and 1200 kiloliters. Employing an in-house Software Program developed for the Design of Elevated Circular Water Tanks and adhering to the guidelines of IS 3370:2021, the study conducts a thorough parameter comparison to reveal substantial cost savings achievable through strategic H/D ratio selection. Particularly noteworthy is the revelation that the H/D ratio optimizing cost aligns with the configuration that experiences minimal wind and seismic forces. Informed parameter choices emerge as a driving force behind considerable reductions in material consumption, underscoring the software program's efficacy as a pivotal tool for designing elevated water tanks, particularly in scenarios where conventional analysis and design software lack accessibility.

Author Biographies

  • Sukanya Saxena, Indian Institute of Technology (B.H.U) Varanasi 221005 India

    Research Scholar

    Department of Civil Engineering Indian Institute of Technology (B.H.U), Varanasi 221 005, India

  • Krishna Kant Pathak, Professor Department of Civil Engineering Indian Institute of Technology (B.H.U) Varanasi 221005 India
    Prof. Krishna Kant Pathak Professor Department of Civil Engineering, IIT (BHU) kkpathak.civ@iitbhu.ac.in 9425303685 Area of Interest:  Structural Engineering – Continuum Mechanics; Structural Analysis & Design; Structural Shape Optimization; Finite Element Analysis; Building Materials

Downloads

Published

2024-06-26

How to Cite

Comprehensive study of cost, seismic & wind impacts on circular water tanks with varying cylindrical height-to-diameter ratio. (2024). Indian Journal of Engineering and Materials Sciences (IJEMS), 31(2), 224-231. https://doi.org/10.56042/ijems.v31i2.5368